18kVA, Single Phase, Standby Diesel Generator with Kubota Engine in Canopy
Model No.: ED18KYE
The Kubota powered ED18KYE is a 18kVA single phase standby diesel generator. Complete with Crossley SLG series single bearing, 4-pole, brushless alternator, remote start/stop control system, 90 litre fuel tank, weather protective acoustic canopy and Kubota engine. Welling and Crossley Kubota powered generating sets are fully integrated power generation systems that are stringently tested to provide optimum performance, reliability, and versatility for standby applications.
Alternator
Alternator Model: Crossley
Electric Power: Single Phase
Active Rating: 18 kVA at 0.8 pf (Standby)
Power: 14.4 kW
Voltage: 240V
Frequency: 50Hz
Engine
Engine Model: Kubota D1803-M
Engine Speed: 1500 rpm
Cylinder No.: 3
Cubic Capacity: 1.826 L
Bore / Stroke: 87 x 92.4 mm
Compression Ratio: 16 : 1
Aspiration: Natural
Starter Voltage: 12V
Flywheel ( Max. Continuous Power): 19 kW
Combustion Air Flow: 1.6 m³/min
Cooling Air Flow: 55 m³/min
Cooling System: Radiator Cooled
Heat Rejection to Cooling System: 17 kW
Exhaust Gas Flow: 4.8 m³/min
Exhaust Gas Temperature: 550°C
Fuel Type: Diesel
Fuel Tank Capacity: 90 L
Approx. Fuel Consumption (Continuous): 5.13 L/hr
Approx. Fuel Consumption (Standby): 5.7 L/hr
Generator
Dimensions (L x W x H): 2000 x 900 x 1153 mm (L x W x H)
Weight: 880 kg
*Specifications are subject to change without notice
The control starting system is an Auto-Start Control Module and is fitted standard. Starting is remote or local to the machine with push Start/Stop button and includes the following:
- Alternator frequency & speed sensing
- Fully configurable via the interface or PC using USB
- Generator/load power monitoring
- Accumulated power monitoring
- Generator overload protection
- Fuel and start outputs
- Engine speed protection
- Engine run-time scheduler
- Battery voltage monitoring
- Static battery charger
Can also be configured to operate with an Automatic Transfer Switch with logic.
- Weather protective Acoustic Canopy
A weather protective acoustic enclosure is included, to protect and prolong the life of your generator. Finished using a powder coat paint finish, this acoustic canopy will reduce the noise level of the generating set to approximately 73 dB(A) at 1 metre from the machine (65 dB(A) @ 7 m).
- Heavy duty fabricated steel base frame
The complete generating set is mounted as a whole onto a heavy duty fabricated steel base frame. Anti-vibration pads are fixed between the engine and alternator feet, and the base frame, ensuring complete vibration isolation of the rotating assembly.
- Bunded Fuel Tank (AS 1940-2004 compliant)
The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiently retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance refer to the standard, or contact us.
- Battery Charger
This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.
- Control Panel with Emergency Stop button
This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts large liquid crystal display (LCD) and has a 32 bit micro-processor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.
- Prime or Standby Power
Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).
Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.
For ratings outside this range, please contact us.