5.5kVA, Single Phase, Lister Petter Bore Pump Generator

Model No.: LLT5.5/1BPG

The Lister powered LLT5.5/1BPG is a 5.5kVA single phase diesel generator. The Lister Petter powered range of bore pump generators custom match an engine with an alternator to guarantee that your generator will power any electric motor driven pump without light loading the engine. These generators are controlled by Welling & Crossleys own generator controller, monitoring and protecting  the engine, alternator and pump simultaneously. With Lister Petter’s legendary performance and reliability these units go through a stringent testing process to ensure quality every time.

Alternator

Alternator Model: Crossley SLG Series
Electric Power: Single Phase
Active Rating: 5.5 kVA at 0.8 pf (Standby)
Power: 4.9 kW
Electric Potential: 240V
Frequency: 50Hz

Engine

Engine Model: Lister Petter TR1-09
Engine Speed: 1500 rpm
Cylinder No.: 1
Cubic Capacity: 0.77 L
Bore / Stroke: 98 x 102 mm
Compression Ratio: 15.5 : 1
Aspiration: Natural
Starter Voltage: 12V
Flywheel ( Max. Continuous Power): 5.5 kW
Cooling System: Air Cooled
Fuel Type: Diesel
Fuel Tank Capacity: 90 L
Approx. Fuel Consumption (Continuous): 1.5 L/hr
Approx. Fuel Consumption (Standby): 1.65 L/hr

Generator

Dimensions (L x W x H): 1000 x 760 x 1200 mm (L x W x H)
Weight: 300 kg

*Specifications are subject to change without notice

The control starting system is fitted standard.
Starting is remote or local to the machine with push Start/Stop button and includes the following digital indicators:

  • Oil Pressure
  • Engine Temperature
  • Frequency
  • Volts and Amps
  • Shut Down for low oil & temperature
  • Emergency stop button
  • Output circuit breaker
  • Static Battery Charger
  • Pump pressure reading
  • Pump pressure pre-set cut out values PSI
  • Generator operation mode

The control system has an auto start programmed run event system, and it can be configured to operate with an Automatic Transfer Switch with logic.

  • Oversize Alternator

The alternators fitted to these generators are larger than normally required to aid electric motor starting.

  • Weather protective roof

A weather protective roof is fitted to the generator frame to allow for onsite operation without external structures. These covers reduce generator ware from environmental factors.

  • Heavy duty fabricated steel baseframe

The complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.

  • Bunded Fuel Tank (AS 1940-2004 compliant)

The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiantly retain spillage and enable recovery of any spillage. For more information regarding AS 190-2004 compliance refer to the standard, or contact us.

  • Battery Charger

This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.

  • Control Panel with Emergency Stop button

This control panel can detect both voltage and current and can be started and stopped manually or via remote start stop signals. It displays oil pressure and water/cylinder temperature, and comes standard with an emergency stop alarm, over speed monitor, and graphical LCD monitor.

  • Prime or Standby Power

Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).

Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.
For ratings outside this range, please contact us.

  • Additional Protection Alarms
  • Jacket Heater
  • Automatic Transfer Switch (ATS)
  • Control System (remote Start/Stop) with Mains Failure option
  • Trailer mounted
  • Load Banks
  • Auxiliary Fuel Tanks
  • Genuine Spare Parts