92kW @ 2200 RPM Lister Petter Gamma Series Diesel Engine – Water Cooled

Model No.: GWT6-2A-22-IRRI

Lister Petter water cooled diesel engines are designed with Lister’s legendary performance and reliability. This Gamma series engine is perfect for irrigation and pumping applications. All diesel engines that are sold through Welling and Crossley are stringently tested to ensure quality in their products.

 

Power Rating: 92 kW
Engine Model: LISTER PETTER GWT6-2A
Engine Speed: 2200 RPM
Starter Voltage: 12 V
Cylinder No.: 6
Aspiration: Turbocharged
Starting System: Electric
Approx. Fuel Consumption @ Full Load: 25.3 L/hr
Fuel Type: Diesel
Diam.: 1540x716x1108 (L x W x H)
Weight: 740 kg

Output Standby: 102.2kW (137hp)
Output Continuous: 92kW (123.3hp)
Bell Housing and Fly Wheel: SAE#3,10 and 11.5

Specifications subject to variation without notice.

*Specifications are subject to change without notice

Irrigation Control Panel

The Irrigation Control Panel has been designed to meet the needs of most irrigation and pumping applications without being too technical. Its features were designed to accommodate the requirements of irrigation systems being used in stock watering or Block watering. For example, pumps filling turkey nest tanks around the farm which then gravity feed into watering troughs. Since then the control panel has been in many different applications equally as successful.

It features all the engine protection that is expected of a modern control panel monitoring Oil Pressure, Engine cooling temperature whether the engine is air or water, battery charge voltage and over speed. With a built digital tachometer with two separate odometers which are resettable to monitor service intervals or making fuel economy checks.

The control panel is also configured to read a pressure transducer which is supplied where required that can monitor the water pressure in the delivery line of a pump adding another level of protection to the system. If the pressure exceeds or drops below operator defined levels the controller will stop the engine to protect pipeline and pump.

The Irrigation Control Panel has three different methods which can be used to start the engine:

  • Manual Start – Push the manual button then the Start Button.
  • Auto Timed – In Auto mode a start and run time can be programmed to start daily or use 16 different start event times.
  • Two wire start – close a no voltage two wire circuit to start the engine.

This panel can also accommodate various switches and controllers such as Flow Switches, Vacuum Switch gauges, and pre heaters.

Additional information

Application

Engine

Power Rating (kW)

Cooling